• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Editorial Staff
    • Publication Ethics
    • Indexing and Abstracting
    • Related Links
    • FAQ
    • Peer Review Process
    • News
  • Guide for Authors
  • Submit Manuscript
  • Reviewers
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Arab Journal of Nuclear Sciences and Applications
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 54 (2021)
Volume Volume 53 (2020)
Volume Volume 52 (2019)
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 51 (2018)
Abdalla, A. (2019). CPRD Supplied With Native Scintillator for Radon Gas Detection. Arab Journal of Nuclear Sciences and Applications, 52(3), 90-97. doi: 10.21608/ajnsa.2019.5723.1130
Ayman mohamed Abdalla. "CPRD Supplied With Native Scintillator for Radon Gas Detection". Arab Journal of Nuclear Sciences and Applications, 52, 3, 2019, 90-97. doi: 10.21608/ajnsa.2019.5723.1130
Abdalla, A. (2019). 'CPRD Supplied With Native Scintillator for Radon Gas Detection', Arab Journal of Nuclear Sciences and Applications, 52(3), pp. 90-97. doi: 10.21608/ajnsa.2019.5723.1130
Abdalla, A. CPRD Supplied With Native Scintillator for Radon Gas Detection. Arab Journal of Nuclear Sciences and Applications, 2019; 52(3): 90-97. doi: 10.21608/ajnsa.2019.5723.1130

CPRD Supplied With Native Scintillator for Radon Gas Detection

Article 10, Volume 52, Issue 3, July 2019, Page 90-97  XML PDF (844.19 K)
Document Type: Original Article
DOI: 10.21608/ajnsa.2019.5723.1130
Author
Ayman mohamed Abdalla email
Najran university, Najran, KSA najran
Abstract
For neutron detection and radioactive gas sensing, it is greatly beneficial to detect alpha (α) particles and gamma rays. In present work, continues passive radon detector (CPRD) has been constructed with native ZnS; Ag.Cl scintillator. The detector has been supplied with high efficient native nano particles scintillator for detection α particles. One of the features of this scintillator, the energy resolution is comparable with or even better than commercial ZnS(Ag) scintillator. This study provides an alternative for fabrication the native scintillator in absence of costly scintillator available in the market. Moreover, results of scintillation characteristics, along with physical properties of the scintillator are addressed and thoroughly discussed. For calibration, radon calibration system with dual radon monitor has been constructed in Najran University, Saudi Arabia. The experimental sensitivity of the passive CPRD cell for radon gas detection was constant with well know data already published in the literatures. Radon emission from natural sample has been measured by the fabricated CPRD cell.
Keywords
Radon gas detection; Calibration chamber; sensitivity; ZnS; Ag.Cl scintillator